Projection Height Range |
| |
Lancer-1
Only |
LANCER-1
and LANCER-2 |
LANCER-2
Only |
Trip Gage |
|
Stud Size |
#8, #10, M4, M5 |
1/4", M6, M7 |
5/16", M8 |
3/8", 7/16", M10 |
|
Inches |
mm |
Inches |
mm |
Inches |
mm |
Inches |
mm |
|
|
Stud Projections |
MIN |
.313" |
7.9mm |
.406" |
10.3mm |
.500" |
12.7mm |
.500" |
12.7mm |
#1 Open Gage |
|
MAX |
.470 |
11.9 |
.525 |
13.3 |
.750 |
19.0 |
.625 |
15.9 |
|
MIN |
.406 |
10.3 |
.500 |
12.7 |
.594 |
15.1 |
.594 |
15.1 |
#10 Gage |
|
MAX |
1.625 |
41.2 |
1.719 |
43.6 |
1.813 |
46.0 |
1.813 |
46.0 |
|
MIN |
.556 |
14.1 |
.650 |
16.5 |
.744 |
18.9 |
.744 |
18.9 |
#10-AL
Auto-Load Gage |
|
MAX |
1.775 |
45.1 |
1.869 |
47.4 |
1.963 |
49.8 |
1.963 |
49.8 |
|
MIN |
.811 |
20.6 |
.905 |
23.0 |
1.000 |
25.4 |
- |
- |
LANCER-1
#10-ML
Machine Load Gage |
|
MAX |
2.027 |
51.5 |
2.122 |
53.9 |
2.216 |
56.3 |
- |
- |
|
MIN |
- |
- |
.822 |
20.9 |
.916 |
23.3 |
.916 |
23.3 |
LANCER-2
#10-ML
Machine Load Gage |
|
MAX |
- |
- |
2.041 |
51.8 |
2.135 |
54.2 |
2.135 |
54.2 |
|
MIN |
1.563 |
39.7 |
1.656 |
42.0 |
1.750 |
44.4 |
1.750 |
44.4 |
#11 Gage
#11-AL Gage
#11-ML Gage |
|
MAX |
2.781 |
70.6 |
2.875 |
73.0 |
2.969 |
75.4 |
2.969 |
75.4 |
NOTE: ±.031"
or ±0.8mm tolerance on
all projection heights.
If stud projection requirements are longer or shorter
than those shown above, consult TITAN TOOL COMPANY for special
options or tool modifications. |
|
Projection Height Adjustment |
Tools shown are Lancer-2's equipped with a #10 Gage.
Increasing the distance between lock rings "A" and "B" will
produce a corresponding increase in the set projection height.

|
|
Two Stage, Anti-Strip
Loading / Unloading Cycles |
Whenever the LANCER is used on a
projection height application it is essential that you specify that the tool
be equipped with a "P" Body. The "P" Body allows the
Drive tang and slot to completely disengage. This totally isolates the
body, jaws and stud from any rotational force.
This unique two stage loading / unloading cycle
prevents thread damage that commonly occurs with projection height stud
drivers that utilize a conventional single stage design.
Exception: If projection height of stud is
controlled by Spindle Stop, and Spindle Rotation stops at the same time as
Spindle Feed stops, then use ET-Body for improved performance.
|

|
|